ZENEX Multi-System

R-System

Features

Components

Mini (Ø 3.5)

Regular (Ø 4.0)

Regular (Ø 4.5)

Wide (Ø 5.0)

Wide (Ø 5.5)

Wide (Ø 6.0)

Wide (Ø 7.0)

Mini (Ø 3.5)

  • Internal 5º tapered submerged type implant
  • SLA surface implant
  • Tapered design to secure initial stability
  • Double thread design for securing width of internal connection and easy insertion
  • Possible to secure primary stability on apex of fixture by realizing wide apical diameter.
  • Recommended torque for implant placement: Less than 40Ncm

Regular (Ø 4.0)

  • Internal 5º tapered submerged type implant
  • SLA surface implant
  • Tapered design to secure initial stability
  • Double thread design for securing width of internal connection and easy insertion
  • Possible to secure primary stability on apex of fixture by realizing wide apical diameter.
  • Recommended torque for implant placement: Less than 40Ncm

Regular (Ø 4.5)

  • Internal 5º tapered submerged type implant
  • SLA surface implant
  • Tapered design to secure initial stability
  • Double thread design for securing width of internal connection and easy insertion
  • Possible to secure primary stability on apex of fixture by realizing wide apical diameter.
  • Recommended torque for implant placement: Less than 40Ncm
  • Recommend to use fixture bigger than Ø4.5 mm for single case in posterior area

Wide (Ø 5.0)

  • Internal 5º tapered submerged type implant
  • SLA surface implant
  • Tapered design to secure initial stability
  • Double thread design for securing width of internal connection and easy insertion
  • Possible to secure primary stability on apex of fixture by realizing wide apical diameter.
  • Recommended torque for implant placement: Less than 40Ncm
  • Recommend to use fixture bigger than Ø4.5 mm for single case in posterior area

Wide (Ø 5.5)

  • Internal 5º tapered submerged type implant
  • SLA surface implant
  • Tapered design to secure initial stability
  • Double thread design for securing width of internal connection and easy insertion
  • Possible to secure primary stability on apex of fixture by realizing wide apical diameter.
  • Recommended torque for implant placement: Less than 40Ncm
  • Recommend to use fixture bigger than Ø4.5 mm for single case in posterior area

Wide (Ø 6.0)

  • Internal 5º tapered submerged type implant
  • SLA surface implant
  • Tapered design to secure initial stability
  • Double thread design for securing width of internal connection and easy insertion
  • Possible to secure primary stability on apex of fixture by realizing wide apical diameter.
  • Recommended torque for implant placement: Less than 40Ncm
  • Wide fixture with single thread for easy implant placement.
  • 6mm length fixture enables to use in lower alveolar bone
  • Radial shaped on upper part of fixture enables to be used for wide hole such as extraction socket
  • Recommend to use fixture bigger than Ø4.5 mm for single case in posterior area

Wide (Ø 7.0)

  • Internal 5º tapered submerged type implant
  • SLA surface implant
  • Tapered design to secure initial stability
  • Double thread design for securing width of internal connection and easy insertion
  • Possible to secure primary stability on apex of fixture by realizing wide apical diameter.
  • Recommended torque for implant placement: Less than 40Ncm
  • Wide fixture with single thread for easy implant placement.
  • 6mm length fixture enables to use in lower alveolar bone
  • Radial shaped on upper part of fixture enables to be used for wide hole such as extraction socket
  • Recommend to use fixture bigger than Ø4.5 mm for single case in posterior area