ZENEX Multi-System

R-System

Abutment

Healing Abutment

  • Use Healing Abutment fits for the diameter of abutment.
  • Select specification fits for fixture connection.
  • Tighten with 1.2 Hex Driver by hand
  • Recommended tightening torque: 5~8Ncm
  • Select appropriate fixture height upon depth of implant placement.
  • Select specification fits for fixture connection.
  • Tighten with 1.2 Hex Driver by hand
  • Recommended tightening torque: 5~8Ncm
  • Abutment for manufacturing Screw-retained type temporary prosthesis
  • Select specification fits for fixture connection.
  • Fixture Level Impression
  • Tighten with 1.2 Hex Driver
  • Recommended tightening torque: 20Ncm
  • To order as a set as 'Abutment + Abutment Screw' :
    Product Code + S (ex: TARRH4010S)
  • Abutment for manufacturing Cement/Combination-retained type prosthesis
  • Select specification fits for fixture connection.
  • Customized by grinding (need to be maintained at least 3.0mm of Abutment Length above Fixture Platform)
  • Fixture Level Impression
  • Tighten with 1.2 Hex Driver
  • Recommended tightening torque: 30Ncm
  • To order as a set as 'Abutment + Abutment Screw' :
    Product Code + S (ex: CARRH40205S)

Angled Abutment

  • Abutment for manufacturing Cement/Combination-retained type prosthesis
  • Various types of Angle (15º & 25º)
  • Select specification fits for fixture connection.
  • Fixture Level Impression
  • Can be positioned in 12 directions by selecting A or B type
  • Tighten with 1.2 Hex Driver
  • Recommended tightening torque: 30Ncm
  • To order as a set as 'Abutment + Abutment Screw' :
    Product Code + S (ex: AARRA40152S)

FreeMilling Abutment

  • Abutment for manufacturing Cement/Combination-retained type prosthesis
  • Used when creating free marginal space for Abutment
  • Select specification fits for fixture connection.
  • Customized by grinding (need to be maintained at least 3.0mm of Abutment Length above Fixture Platform)
  • Fixture Level Impression
  • Tighten with 1.2 Hex Driver
  • Recommended tightening torque: 30Ncm
  • To order as a set as 'Abutment + Abutment Screw' :
    Product Code + S (ex: FMARRH40209S)

CCM Cast Abutment

  • Abutment for manufacturing customized abutment in difficult and complicated cases
  • Select specification fits for fixture connection.
  • Fixture Level Impression
  • Casting with non-precious alloy for manufacturing customized prosthesis
  • Melting point of CCM: 1,400 ~ 1,550℃
  • Tighten with 1.2 Hex Driver
  • Recommended tightening torque: 30Ncm
  • To order as a set as 'Abutment + Abutment Screw' :
    Product Code + S (ex: CCARRH4010S)

Multi Straight Abutment

  • Abutment for manufacturing screw-retained prosthesis in Multiple Case
  • Same platform as Multi Angled Abutment
  • Move into internal oral part by using exclusive Abutment Carrier (Code: MSACR48)
  • Tighten with exclusive driver (Code: MSADSR20)
  • Recommended tightening torque: 30Ncm
  • To order as a set as 'Abutment + Carrier' :
    Product Code + S (ex: MSARR4815S)

Multi Angled Abutment

  • Abutment for manufacturing screw-retained prosthesis in Multiple Case
  • Abutment of various angles (17º, 30º) for various angled of implant insertion path
  • Same platform as Multi Straight Abutment
  • Compensation of fixture placement angle up to 108º
  • Connect by using exclusive Abutment Carrier (Code: MAACRMC)
  • Tighten with 1.2 Hex driver
  • Recommended tightening torque: 30Ncm
  • Angled Abutment Screw (MAASRR20) included
  • To order as a set as 'Abutment + Carrier':
    Product Code + S (ex: MAARRH481725S)
  • Three kinds of cylinder component for Multi Abutments
  • Multi Healing Cap
  • Abutment for overdenture using O-ring attachment
  • Compensation of mounting angle up to 20º
  • Tighten with exclusive Ball Abutment Driver (Code: BAD24)
  • Recommended tightening torque: 30Ncm
  • Ball Abutment Cap Set & Ball Abutment Retainer Set
  • 5 ea of O-ring are composed with a Ball Abutment O-ring Set
  • Compensation of fixture placement up to 40º
  • 1.5mm lower vertifical dimension
  • Composition of multiple attachments with stable retention
  • Connect with exclusive driver
  • Recommended tightening torque: 30Ncm

Kerator Angled Abutment

  • 1.5mm lower vertifical dimension
  • Composition of multiple attachments with stable retention
  • Connect with 1.2 Hex driver
  • Recommended tightening torque: 30Ncm
  • CDPH Set: White spacer / Denture Cap & Three kinds of Male Cap (Red, Blue, Pink)
  • Seven kinds of Male Cap, according to the retention

Impression Components

Pick-up Impression Coping

  • Components for Fixture Level Impression
  • Open Tray Type
  • Select specification fits for fixture connection
  • Enables accurate impression with design of stably fixed in impression material
  • Tighten with 1.2 Hex Driver by hand
  • To order as a set as 'Impression Coping Body + Guide Pin' :
    [For 11mm Length] Product Code + S (ex: PIRRH40SS)
    [For 15mm Length] Product Code + S (ex: PIRRH40LS)

Transfer Impression Coping

  • Components for Fixture Level Impression
  • Closed Tray Type
  • Select specification fits for fixture connection
  • Streamlined Shape: Easy to transfer
  • Anti-Rotation Grooves accord with Hex of fixture
  • Tighten with 1.2 Hex Driver by hand
  • To order as a set as 'Impression Coping Body + Guide Pin' :
    [For 9mm Length] Product Code + S (ex: TIRRH40SS)
    [For 13mm Length] Product Code + S (ex: TIRRH40LS)

Fixture Lab Analog

  • Lab Analog for Fixture Level Impression
  • Select among Fixture Diameter (Ø 3.5 / Ø 4.0 and above)

Multi Impression Coping

  • Two kinds of impression coping for taking Abutment Level impression for Multi Abutments
  • Open Tray Type for Multi Pick-up Impression Coping
  • Closed Tray Type for Multi Transfer Impression Coping
  • Tighten with 1.2 Hex Driver by hand
  • In the Multi Pick-up Impression Coping, Multi Pick-up Impression Coping Guide Pin (MPICSRGP) included.
  • To order a Multi Pick-up Impression Coping as a set
    as 'Impression Coping Body + Guide Pin':
    Product Code + S (ex: MPICSR48S)

Multi Lab Analog

  • Lab Analog for Multi Abutment

Ball Abutment Lab Analog

  •  Lab Analog for Ball Abutment

Kerator Impression Coping

  • Pick-up Impression coping for Kerator Abutment
  • Closed Tray Type

Kerator Lab Analog

  • Lab Analog for Kerator Abutment

Digital

ScanBody

  • ScanBody for manufacturing customized Titanium abutment
  • Use for Oral scan (Model scan available as well)
  • Tighten with 1.2 Hex Driver by hand
  • To order as a set as 'ScanBody + ScanBody Screw' :
    Product Code + S (ex: RSBR4310S)
  • Abutment for manufacturing Cement/Combination-retained type prosthesis
  • For manufacturing custom abutment (Titanium & Zirconia) and crown by CAD/CAM equipment
  • Select specification fits for fixture Connection
  • Use exclusive library for Zenex Multi Implant system
  • Fixture Level Impression
  • Tighten with 1.2 Hex driver
  • Recommended tightening torque: 30Ncm
  • To order as a set as 'Abutment + Screw' :
    Product Code + S (ex: TLARRH4010S)

Ti-Blank Abutment

  • Manufacturing customized abutment with milling machine
  • Select specification fits for fixture Connection
  • Digital Impression
  • Tighten with 1.2 Hex driver
  • Recommended tightening torque: 30Ncm
  • Product line-up applied for various milling machine brands
    (Milling machine manufacturer: Doowon, Manix, Vatech, RND)
  • To order as a set as 'Abutment + Screw' :
    Product Code + S (ex: TBARRH10AS)
  • Multi Cylinder for making Combination-retained prosthesis from Multi Abutment.
  • Use when producing Customized Abutment (Titanium & Zirconia) and Crown by CAD/CAM equipment.
  • Use exclusive implant library of Zenex Multi Implant System
  • Abutment Level Impression
  • Tighten with 1.2 Hex driver
  • Recommended tightening torque: 20Ncm
  • Multi Cylinder Screw (MTCSR23) included
  • To order as a set as 'Cylinder + Multi Cylinder Screw' :
    Product Code + S (ex: MTLCSRN48S)

Prosthetic Flow Chart

Flow Chart I

Flow Chart II

Flow Chart III

Flow Chart IV